MUTAI AC 400V 3P+N 50A 63A 80A 100A 125A 160A 180A 250A Smart Recloser Automatic Disyuntor Circuit Breaker
Product Details
CMTM5L series residual current protection circuit breaker is a newly developed product of our company. It is an integrated, multifunctional, overcurrent adjustable circuit breaker, suitable for low-voltage power grid with three-phase four-wire neutral point directly grounded. It can provide indirect contact protection against personal electric shock hazards, and can also protect against grounding faults, overcurrent, short circuits, etc. of lines or electricity.
The product conforms with the standard of IEC60947-1
Type | CMTM5L-125 | CMTM5L-250 | CMTM5L-400 | CMTM5L-630 | |
Pole | 3P+N 4P | 3P+N 4P | 3P+N 4P | 3P+N 4P | |
Rated Working Voltage Ue(v) | AC 400 50Hz | ||||
Rated Insulation Voltage Ui(v) | 8000 | ||||
Rated Impluse Withstand | 8000 | ||||
Voltage Uimp(v) | |||||
Flashover Distance | ≥50 | ≥50 | ≥100 | ≥100 | |
Rated Ultimate Short Circuit | 50 | 50 | 65 | 65 | |
Breaking Capacity Lcu(ka) | |||||
Rated Serviec Short Circuit | 35 | 35 | 42 | 50 | |
Breaking Capacity Lcs(ka) | |||||
Rated Residual Short Circuit | 12.5 | 12.5 | 20 | 20 | |
Breaking Capacity (ka) | |||||
Rated Short time | 1.5kA/1s | 3kA/0.5s | 5kA/0.5s | 8kA/0.5s | |
Withstand Current Icw(ka) | |||||
Residual Current Action Character Istics | AC Type | ||||
Rated Residual Operating Current | 100mA,300mA,500mA,1000mA(Adjustable grading) | ||||
Ratedual Action Time Character Istics | Time-delay Type(0.5s)/non Time-delay Type(0.3) | ||||
time-delay type limit non-acting time(s) | t≥0.06 :2l n | ||||
Breaking Time(s) | l n≤0.5; 21 n≤0.2; 5lAn≤0.15 | ||||
Automatic Realosing Time | 20-60 | ||||
Operting | No | 1500 | 1000 | 1000 | 2000 |
performance | OFF | 8500 | 7000 | 4000 | 8000 |
(times) | Total times | 10000 | 8000 | 5000 | 10000 |
Overloa short circuit characteristic | Three-sect Protection Electronic Adjustable | ||||
Detailed"descrIption Of Protection Features" | |||||
over-voltage protection value(V) | Value(250~300)±5% | ||||
Under voltage protection value(V) | Value (150~200)±5% | ||||
joint control delay time(ms) | ≤40ms | ||||
Comunication delay time(ms) | ≤200ms |
Size
Model | CMTM5L-125 | CMTM5L-250 | CMTM5L-400/630 | CMTM5L-800 | |
dimensions | L | 220 | 240 | 336 | 370 |
L1 | 202 | 220 | 303 | 336 | |
L2 | 320 | 370 | 539 | 580 | |
L3 | 168.5 | 177 | 253 | 254 | |
H | 64 | 89 | 101 | 107 | |
H1 | 118 | 136 | 183 | 188 | |
H2 | 28.5 | 25 | 42.5 | 42.5 | |
W | 122 | 142 | 198 | 280 | |
Installation Dimensions | W1 | 30 | 35 | 48 | 70 |
A | 30 | 35 | 48 | 70 | |
B | 199 | 201 | 272 | 333 | |
G | 18 | 23 | 32 | 44 | |
G1 | 7 | 11.5 | 12 | 12 | |
Φd | Φ4.5 | Φ5 | Φ8.5 | Φ8.5 | |
M | M8 | M8 | M10 | M12 |
Advantage
1.Intelligent
The intelligent control circuit adopts microcomputer chip control technology, with high precision, accurate and reliable action, adjustable over-current protection value, and is not affected by ambient temperature.
2. Full protection function
The product has all the protection functions of intelligent molded case circuit breakers, and also has protection functions such as leakage delay, overvoltage delay, and undervoltage delay.
3. Multi-state display measurement function
It has the functions of displaying parameters such as voltage, current, communication, leakage, and automatically tracking leakage setting values.
4.Selective reclosing function
The product has the function of automatic reclosing after leakage, overvoltage, undervoltage and other faults are eliminated.
5. High breaking capacity
The product uses high-breaking molded case circuit breaker as the main body, which has the characteristics of small size, compact structure and high breaking capacity. The maximum breaking current can reach 50kA.
6.Automatically memorize running data
7.Strong anti-interference ability
The electronic components of the product have SPDK^ function. According to user needs, the maximum flow capacity can reach 40LA.
8.Automatic detection function after power on
When the product is powered on, it automatically checks whether the voltage is normal, and only allows closing the circuit breaker when it is normal.
9.Communication
Adopt DL/Txxx-xxxx residual current protector communication protocol to realize on-site data collection and remote monitoring functions
Application
The circuit breakers are professional & widely used in building, residence, industrial applications , electric power transmission.
Others
Packaging
5 pcs per carton
Dimension per outer box: 38*37*29 cm
Main Market
MUTAI Electric focus on Middle East, Africa, South East Asia, South America, Russia Market.